您好,欢迎访问山东省农业科学院文献资源数据库平台

Detection of Salmonella Typhimurium on Spinach Using Phage-Based Magnetoelastic Biosensors

文献类型: 外文期刊

作者: Wang, Fengen 1 ; Horikawa, Shin 2 ; Hu, Jiajia 3 ; Wikle, Howard C., III 2 ; Chen, I-Hsuan 4 ; Du, Songtao 2 ; Liu, Yu 1 ;

作者机构: 1.Shandong Acad Agr Sci, Inst Qual Stand & Testing Technol Agroprod, Jinan 250100, Peoples R China

2.Auburn Univ, Mat Res & Educ Ctr, Auburn, AL 36849 USA

3.Changzhou Univ, Jiangsu Key Lab Mat Surface Technol, Sch Mat Sci & Engn, Changzhou 213164, Peoples R China

4.Auburn Univ, Dept Biol Sci, Auburn, AL 36849 USA

关键词: Salmonella Typhimurium;spinach;magnetoelastic;biosensors

期刊名称:SENSORS ( 影响因子:3.576; 五年影响因子:3.735 )

ISSN: 1424-8220

年卷期: 2017 年 17 卷 2 期

页码:

收录情况: SCI

摘要: Phage-based magnetoelastic (ME) biosensors have been studied as an in-situ, real-time, wireless, direct detection method of foodborne pathogens in recent years. This paper investigates an ME biosensor method for the detection of Salmonella Typhimurium on fresh spinach leaves. A procedure to obtain a concentrated suspension of Salmonella from contaminated spinach leaves is described that is based on methods outlined in the U.S.FDA Bacteriological Analytical Manual for the detection of Salmonella on leafy green vegetables. The effects of an alternative pre-enrichment broth (LB broth vs. lactose broth), incubation time on the detection performance and negative control were investigated. In addition, different blocking agents (BSA, Casein, and Superblock) were evaluated to minimize the effect of nonspecific binding. None of the blocking agents was found to be superior to the others, or even better than none. Unblocked ME biosensors were placed directly in a concentrated suspension and allowed to bind with Salmonella cells for 30 min before measuring the resonant frequency using a surface-scanning coil detector. It was found that 7 h incubation at 37 degrees C in LB broth was necessary to detect an initial spike of 100 cfu/25 g S. Typhimurium on spinach leaves with a confidence level of difference greater than 95% (p < 0.05). Thus, the ME biosensor method, on both partly and fully detection, was demonstrated to be a robust and competitive method for foodborne pathogens on fresh products.

  • 相关文献

[1]Alternative Soaking Media for the FDA Procedure in the Detection of Salmonella from Tomatoes and Spinach Leaf using Phage Magnetoelastic Biosensors. Chen, I-Hsuan,Horikawa, Shin,Barbaree, James M.,Chin, Bryan A.,Hu, Jiajia,Wang, Fengen. 2016

[2]ZEOLITE AS SLOW RELEASE FERTILIZER ON SPINACH YIELDS AND QUALITY IN A GREENHOUSE TEST. Li, Zhaohui,Li, Zhaohui,Zhang, Yingpeng,Li, Yan,Zhang, Yingpeng,Li, Yan. 2013

作者其他论文 更多>>